diff options
author | Cristian Maglie <c.maglie@bug.st> | 2012-01-04 15:14:51 +0100 |
---|---|---|
committer | Cristian Maglie <c.maglie@bug.st> | 2012-01-04 15:14:51 +0100 |
commit | 8c2b5b979a75d109ae7cc306afc50d7ffe1e0366 (patch) | |
tree | 19ac8d91c7209397e7dc890b432a254ae9a7cd62 /libraries/Ethernet/examples/BarometricPressureWebServer | |
parent | be52c95820400d48e47615232d3c38236166fad3 (diff) |
Moved libraries folder inside platform folder. Now libraries and examples are searched per board/platform
Diffstat (limited to 'libraries/Ethernet/examples/BarometricPressureWebServer')
-rw-r--r-- | libraries/Ethernet/examples/BarometricPressureWebServer/BarometricPressureWebServer.ino | 222 |
1 files changed, 222 insertions, 0 deletions
diff --git a/libraries/Ethernet/examples/BarometricPressureWebServer/BarometricPressureWebServer.ino b/libraries/Ethernet/examples/BarometricPressureWebServer/BarometricPressureWebServer.ino new file mode 100644 index 0000000..bfbcb6d --- /dev/null +++ b/libraries/Ethernet/examples/BarometricPressureWebServer/BarometricPressureWebServer.ino @@ -0,0 +1,222 @@ +/* + SCP1000 Barometric Pressure Sensor Display + + Serves the output of a Barometric Pressure Sensor as a web page. + Uses the SPI library. For details on the sensor, see: + http://www.sparkfun.com/commerce/product_info.php?products_id=8161 + http://www.vti.fi/en/support/obsolete_products/pressure_sensors/ + + This sketch adapted from Nathan Seidle's SCP1000 example for PIC: + http://www.sparkfun.com/datasheets/Sensors/SCP1000-Testing.zip + + Circuit: + SCP1000 sensor attached to pins 6,7, and 11 - 13: + DRDY: pin 6 + CSB: pin 7 + MOSI: pin 11 + MISO: pin 12 + SCK: pin 13 + + created 31 July 2010 + by Tom Igoe + */ + +#include <Ethernet.h> +// the sensor communicates using SPI, so include the library: +#include <SPI.h> + + +// assign a MAC address for the ethernet controller. +// fill in your address here: +byte mac[] = { + 0xDE, 0xAD, 0xBE, 0xEF, 0xFE, 0xED}; +// assign an IP address for the controller: +IPAddress ip(192,168,1,20); +IPAddress gateway(192,168,1,1); +IPAddress subnet(255, 255, 255, 0); + + +// Initialize the Ethernet server library +// with the IP address and port you want to use +// (port 80 is default for HTTP): +EthernetServer server(80); + + +//Sensor's memory register addresses: +const int PRESSURE = 0x1F; //3 most significant bits of pressure +const int PRESSURE_LSB = 0x20; //16 least significant bits of pressure +const int TEMPERATURE = 0x21; //16 bit temperature reading + +// pins used for the connection with the sensor +// the others you need are controlled by the SPI library): +const int dataReadyPin = 6; +const int chipSelectPin = 7; + +float temperature = 0.0; +long pressure = 0; +long lastReadingTime = 0; + +void setup() { + // start the SPI library: + SPI.begin(); + + // start the Ethernet connection and the server: + Ethernet.begin(mac, ip); + server.begin(); + + // initalize the data ready and chip select pins: + pinMode(dataReadyPin, INPUT); + pinMode(chipSelectPin, OUTPUT); + + Serial.begin(9600); + + //Configure SCP1000 for low noise configuration: + writeRegister(0x02, 0x2D); + writeRegister(0x01, 0x03); + writeRegister(0x03, 0x02); + + // give the sensor and Ethernet shield time to set up: + delay(1000); + + //Set the sensor to high resolution mode tp start readings: + writeRegister(0x03, 0x0A); + +} + +void loop() { + // check for a reading no more than once a second. + if (millis() - lastReadingTime > 1000){ + // if there's a reading ready, read it: + // don't do anything until the data ready pin is high: + if (digitalRead(dataReadyPin) == HIGH) { + getData(); + // timestamp the last time you got a reading: + lastReadingTime = millis(); + } + } + + // listen for incoming Ethernet connections: + listenForEthernetClients(); +} + + +void getData() { + Serial.println("Getting reading"); + //Read the temperature data + int tempData = readRegister(0x21, 2); + + // convert the temperature to celsius and display it: + temperature = (float)tempData / 20.0; + + //Read the pressure data highest 3 bits: + byte pressureDataHigh = readRegister(0x1F, 1); + pressureDataHigh &= 0b00000111; //you only needs bits 2 to 0 + + //Read the pressure data lower 16 bits: + unsigned int pressureDataLow = readRegister(0x20, 2); + //combine the two parts into one 19-bit number: + pressure = ((pressureDataHigh << 16) | pressureDataLow)/4; + + Serial.print("Temperature: "); + Serial.print(temperature); + Serial.println(" degrees C"); + Serial.print("Pressure: " + String(pressure)); + Serial.println(" Pa"); +} + +void listenForEthernetClients() { + // listen for incoming clients + EthernetClient client = server.available(); + if (client) { + Serial.println("Got a client"); + // an http request ends with a blank line + boolean currentLineIsBlank = true; + while (client.connected()) { + if (client.available()) { + char c = client.read(); + // if you've gotten to the end of the line (received a newline + // character) and the line is blank, the http request has ended, + // so you can send a reply + if (c == '\n' && currentLineIsBlank) { + // send a standard http response header + client.println("HTTP/1.1 200 OK"); + client.println("Content-Type: text/html"); + client.println(); + // print the current readings, in HTML format: + client.print("Temperature: "); + client.print(temperature); + client.print(" degrees C"); + client.println("<br />"); + client.print("Pressure: " + String(pressure)); + client.print(" Pa"); + client.println("<br />"); + break; + } + if (c == '\n') { + // you're starting a new line + currentLineIsBlank = true; + } + else if (c != '\r') { + // you've gotten a character on the current line + currentLineIsBlank = false; + } + } + } + // give the web browser time to receive the data + delay(1); + // close the connection: + client.stop(); + } +} + + +//Send a write command to SCP1000 +void writeRegister(byte registerName, byte registerValue) { + // SCP1000 expects the register name in the upper 6 bits + // of the byte: + registerName <<= 2; + // command (read or write) goes in the lower two bits: + registerName |= 0b00000010; //Write command + + // take the chip select low to select the device: + digitalWrite(chipSelectPin, LOW); + + SPI.transfer(registerName); //Send register location + SPI.transfer(registerValue); //Send value to record into register + + // take the chip select high to de-select: + digitalWrite(chipSelectPin, HIGH); +} + + +//Read register from the SCP1000: +unsigned int readRegister(byte registerName, int numBytes) { + byte inByte = 0; // incoming from the SPI read + unsigned int result = 0; // result to return + + // SCP1000 expects the register name in the upper 6 bits + // of the byte: + registerName <<= 2; + // command (read or write) goes in the lower two bits: + registerName &= 0b11111100; //Read command + + // take the chip select low to select the device: + digitalWrite(chipSelectPin, LOW); + // send the device the register you want to read: + int command = SPI.transfer(registerName); + // send a value of 0 to read the first byte returned: + inByte = SPI.transfer(0x00); + + result = inByte; + // if there's more than one byte returned, + // shift the first byte then get the second byte: + if (numBytes > 1){ + result = inByte << 8; + inByte = SPI.transfer(0x00); + result = result |inByte; + } + // take the chip select high to de-select: + digitalWrite(chipSelectPin, HIGH); + // return the result: + return(result); +} |